10 - 2
Show Data Format
Scan the bar code below to show current data format settings.
Test Menu
When you scan the Test Menu On code, then scan a programming code in this
manual, the scanner displays the content of a programming code. The pro-
gramming function will still occur, but in addition, the content of that program-
ming code is output to the terminal.
Note: This feature should not be used during normal scanner operation.
TotalFreedom
TotalFreedom is an open system architecture that makes it possible for you cre-
ate applications that reside on your scanner. Decoding apps and Data Format-
ting apps can be created using TotalFreedom. For further information about
TotalFreedom, go to our website at
www.honeywellaidc.com.
Data Format Settings
DFMBK3?.
On
* Off

Table of Contents

Other manuals for Honeywell XENON 1900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g