Page #77 background image
2 - 25
RS232 Word Length: Data Bits, Stop Bits, and Parity
Data Bits sets the word length at 7 or 8 bits of data per character. If an
application requires only ASCII Hex characters 0 through 7F decimal (text,
digits, and punctuation), select 7 data bits. For applications that require
use of the full ASCII set, select 8 data bits per character.
Default = 8.
Stop Bits sets the stop bits at 1 or 2.
Default = 1.
Parity provides a means of checking character bit patterns for validity.
Default = None.
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop Parity None
7 Data, 2 Stop, Parity Odd
8 Data, 1 Stop, Parity Even

Table of Contents

Other manuals for Honeywell XENON 1900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g