4 - 24
To Add an Output Sequence
1. Scan the 
Enter Sequence
 symbol (see Require Output 
Sequence, page 4-27).
2. Code I.D.
On the Symbology Charts on page A-1, find the symbology to which 
you want to apply the output sequence format.  Locate the Hex value 
for that symbology and scan the 2 digit hex value from the 
Programming Chart (inside back cover).
3. Length
Specify what length (up to 9999 characters) of data output will be 
acceptable for this symbology.  Scan the four digit data length from the 
Programming Chart.  (Note:  50 characters is entered as 0050.  9999 
is a universal number, indicating all lengths.)  When calculating the 
length, you must count any programmed prefixes, suffixes, or 
formatted characters as part of the length (unless using 9999).
4. Character Match Sequences
On the ASCII Conversion Chart (Code Page 1252), page A-4, find the 
Hex value that represents the character(s) you want to match.  Use 
the Programming Chart to read the alphanumeric combination that 
represents the ASCII characters.  (99 is the Universal number, 
indicating all characters.)
5. End Output Sequence Editor
Scan 
F F
 to enter an Output Sequence for an additional symbology, or 
Save 
to save your entries.
Other Programming Selections
•
Discard 
This exits without saving any Output Sequence changes.