11 - 4
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands.
First, the scanner must be put in Manual Trigger Mode by scanning a Manual
Trigger Mode bar code (page 4-7), or by sending a serial menu command for
triggering (page 4-9). Once the scanner is in serial trigger mode, the trigger is
activated and deactivated by sending the following commands:
Activate: SYN T CR
Deactivate: SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see "Read Time-
Out" on page 4-9 for a description, and the serial command on page 11-19).
Resetting the Custom Defaults
If you want the custom default settings restored to your scanner, scan the Acti-
vate Custom Defaults bar code below. This resets the scanner to the custom
default settings. If there are no custom defaults, it will reset the scanner to the
factory default settings. Any settings that have not been specified through the
custom defaults will be defaulted to the factory default settings.
Note: If using a cordless system, scanning this bar code also causes both the
scanner and the base or Access Point to perform a reset and become
unlinked. The scanner must be placed in its base to re-establish the link.
If using an Access Point, the linking bar code must be scanned. See
Cordless System Operation beginning on page 3-1 for additional
information.
The charts on the following pages list the factory default settings for each of the
commands (indicated by an asterisk (*) on the programming pages).
Activate Custom Defaults

Table of Contents

Other manuals for Honeywell XENON 1900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g