3 - 21
RAM Storage: The scanner will not power down while it contains data that 
has not been transmitted to the base or Access Point, even if it reaches a 
power down timeout.  However, if the scanner runs out of battery power, it 
will power down and the data will be lost.
Default = Flash Storage.
Batch Mode Quantity
When in Batch Mode, you may wish to transmit the number of multiple bar 
codes scanned, rather than a single bar code multiple times.  For example, 
if you scan three bar codes called XYZ with Batch Mode Quantity Off, 
when you transmit your data it will appear as XYZ three times.  Using 
Batch Mode Quantity On and the Quantity Codes (page 3-22), you could 
output your data as “XYZ, 00003” instead.
Note: If you wish to format your output, for example, place a CR or tab 
between the bar code data and the quantity, refer to Data 
Formatting beginning on page 6-1.
Default = Batch Mode Quantity Off. 
Entering Quantities
Quantity Codes (page 3-22) allow you to enter a quantity for the last item 
scanned, up to 9999 (default = 1).  Quantity digits are shifted from right to 
left, so if a 5th digit is scanned, the 1st digit scanned is discarded and the 
2nd, 3rd and 4th digits are moved to the left to accommodate the new digit.  
For example, if the Quantity 5 bar code is scanned after the quantity has 
been set to 1234, then the 1 is dropped, the quantity will be 2345.
RAM Storage
* Flash Storage
Batch Mode Quantity On