6 - 8
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:  1234567890**ABCDEFGHIJ
<CR>
Insert symbology name
B3 Insert the name of the bar code’s symbology in the output message, 
without moving the cursor.  Only symbologies with a Honeywell ID are 
included (see Symbology Charts on page A-1).  Refer to the ASCII 
Conversion Chart (Code Page 1252), beginning on page A-4 for 
decimal, hex and character codes.
Insert bar code length
B4 Insert the bar code’s length in the output message, without moving the 
cursor.  The length is expressed as a numeric string and does not 
include leading zeroes.
B3 and B4 Example:  Insert the symbology name and length
Send the symbology name and length before the bar code data from 
the bar code above.  Break up these insertions with spaces.  End with 
a carriage return.  
Command string:  B3F42001B4F42001F10D
B3 is the “Insert symbology name” command
F4 is the “Insert a character multiple times” command
20 is the hex value for a space
01 is the number of times the space character is sent
B4 is the “Insert bar code length” command
F4 is the “Insert a character multiple times” command
20 is the hex value for a space
01 is the number of times the space character is sent
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:  Code128 20 1234567890ABCDEFGHIJ
<CR>