INNCOM E7 THERMOSTAT INSTALLATION INSTRUCTIONS
The material in this document is for information purposes only. The content and the product
it describes are subject to change without notice. Honeywell
makes no representations or warranties with respect to this document. In no event shall Honeywell be li
able for technical or editorial omissions or mistakes
in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this document. No part of this document
may be reproduced in any form or by any means without prior written permission from Honeywell.
Co
pyright © 2017 by Honeywell International, Inc. All Rights Reserved.
Honeywell | 277 West Main Street | Niantic, CT 06357 | Phone: 1.860-739-4468 | www.INNCOM.com
CONTRACTOR MODE
Contractor mode allows conditioning a space during the
construction phase to a defined set temperature and locking out
the key pad to prevent tampering. To configure this mode, do the
following:
1. Enter SERVICE MODE:
(1) Press and hold F/C.
(2) Press and hold MODE.
(3) Press and hold FAN.
(4) Release F/C.
2. Use the UP/DOWN arrow buttons to select
ctr.
3. Use the UP/DOWN arrow buttons to select the target
temperature (range: Off - 80 degrees F).
4. Press FAN to continue. Once FAN is pressed, the display
scrolls the set temperature and the unit beeps to confirm
the value has been set.
5. Press F/C to exit SERVICE MODE. The unit dis-
plays the target and measured temperature, and the
alert icon. Any key press to change set temperature,
fan speed or mode are locked out.
EXIT CONTRACTOR MODE
1. Enter SERVICE MODE (Step 1 in the previous section).
2. Use the UP/ DOWN arrows to display - - then press FAN
to turn off CONTRACTOR MODE.
3. Press F/C to exit SERVICE MODE.
Property Specific Configurations
Once initial setup is completed, the e7 can support a range of
expanded Integrated Room Automation System functionality.
This additional functionality is deployed using Honeywell's
software tools INNtool and engINN. Training for INNtool and
engINN for system design and commissioning is now included in
the Level 2 and Level 3 classes.
INNCOM Authorized Systems Integrators should contact their
respective E&ES Regional Support Teams to inquire about
enrolling in upcoming training sessions. If you have already
received training or you are a Honeywell employee supporting the
INNCOM business, you can download the software here:
https://www.inncom.com/login
REGULATORY COMPLIANCE
UL Listing
This device meets UL 60730-2-9, CAN/CSA-E60730-9 Standard for Automatic Electrical Controls -
Part 2-9: Particular Requirements for Temperature Sensing Control
Federal Communications Commission (FCC)
Changes or modifications not expressly approved by Honeywell International, Inc. could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment has been tested
and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This device complies with FCC and IC radiation exposure limits set forth for an uncontrolled
environment. This device should be installed and operated with minimum distance of 20cm between
the radiator and your body. This device must not be co-located or operating in conjunction with any
other antenna or transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Tout changement ou modification n’ayant pas été expressément approuvé par Honeywell
International, Inc. pourrait annuler l’autorisation de l’utilisateur d’utiliser l’équipement.
Cet équipement a subi des tests prouvant sa conformité aux limites prescrites pour les appareils
numériques de classe B, selon la partie 15 des règlements de la FCC. Ces limites ont été conçues pour
fournir une protection raisonnable contre les interférences
nuisibles lorsque l’appareil est utilisé dans un environnement résidentiel. Cet équipement génère,
utilise et peut émettre de l’énergie radioélectrique et, s’il n’est pas installé et utilisé conformément aux
instructions, peut causer des interférences nuisibles aux communications radio. Toutefois, il n’y a
aucune garantie que ces interférences ne puissent survenir dans une installation donnée. Si cet
équipement cause des interférences nuisibles à la réception de signaux de radio ou de télévision, ce
qui peut être déterminé en l’éteignant et en l’allumant, l’utilisateur peut essayer de corriger ces
interférences par les mesures suivantes :
-
Réorienter ou déplacer l’antenne réceptrice.
- Augmenter la distance entre l’équipement et le récepteur.
- Brancher l’équipement sur un circuit différent de celui sur lequel le récepteur est branché.
- Consulter le détaillant ou un technicien expérimenté en radio/télévision pour de l’aide.
Cet
équipement a subi des tests prouvant sa conformité aux limites prescrites pour les appareils
numériques de classe A, selon la partie
15 des règlements de la FCC. Ces limites ont été conçues pour
fournir une protection raisonnable contre les interférences nuisibles lorsque l’appareil est utilisé dans
un environnement commercial. Cet équipementnère, utilise et peut émettre de l’énergie
radioélectrique et, s’il n’est pas installé et utilisé conformément aux instructions, peut causer des
interférences nuisibles aux communications radio. L’utilisation de cet équipement dans une zone
résidentielle est susceptible de causer des interférences nuisibles auquel cas l’utilisateur sera tenu de
corriger ces interférences à ses propres frais
Cet équipement est conforme aux limites d’exposition aux rayonnements FCC et IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20cm
de distance entre la source de rayonnement et votre corps. Cet appareil ne doivent pas être placés à
côté de ou fonctionner en conjonction avec toute autre antenne ou transmetteur.
Industry Canada (IC)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit
pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, me si
le brouillage est susceptible d'en compromettre le fonctionnement.

Other manuals for Honeywell INNCOM e7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell INNCOM e7 and is the answer not in the manual?

Honeywell INNCOM e7 Specifications

General IconGeneral
BrandHoneywell
ModelINNCOM e7
CategoryThermostat
LanguageEnglish

Related product manuals