– 63 –
USER FUNCTIONS
Two-Way Voice Feature (Alarm Audio Verification)
This feature allows an operator at the Central Station to listen, talk to or conduct a two-way conversation with
an individual(s) at your location. It also assists the operator in gathering information about the nature and
location of the alarm that may be helpful in responding to police and/or fire departments. All LYNX Touch
control panels are capable of supporting the Two-Way Voice feature. The LYNX Touch does not make system
announcements when the Two-Way voice feature is active.
If a WiFi connection is being used for Two-Way Voice (AAV), sufficient bandwidth must be available.
AAV requires a continuous WiFi upload/download bandwidth of 90kbps for proper operation.
WiFi bandwidth less than 90kbps may result in degraded performance.
Fire and CO alarms will prevent the LYNX Touch from starting an Two-Way Voice session. A new Fire or
CO alarm will end a Two-Way Voice session that is in progress.
If the Two-way Voice Feature has been programmed and an alarm condition is detected, the system sends an
alarm message to the central station. After acknowledgement is received, a “listen in to follow” message is sent
to the central station. In response to this message, the central station operator can enter commands that allow
initiation of a 5-minute voice session.
When activated, the Two-Way Voice (AAV) feature enters the “Listen Mode” and sirens and keypad sounds are
discontinued. The Central Station operator begins the session, which lasts 5 minutes, and may be extended 5
minutes, without changing the operating mode. If a subsequent security zone is violated during a voice session,
the session will continue and the alarm will be buffered. If a fire zone is violated during a voice session, the
system will terminate the session and process the alarm. The Two-Way Voice modes are described as follows:
Listen Mode: Enables one-way audio from the violated premises to the central station. The Listen Mode is the
start up default mode of the voice feature and allows the operator to listen through the LYNX Touch
microphone.
Talk Mode: Enables one-way voice communication from the central station to the violated premises, and
allows the operator to communicate through the built-in speaker on the LYNX Touch. In this mode the Red
(Armed) and Green (Ready) LEDs blink alternately.
VOX (Voice) Mode: Enables two-way voice communications between the Central Station and the violated
premises via the built-in speaker and microphone on the LYNX Touch. In this mode the Red (Armed) and
Green (Ready) LEDs blink alternately.
During the voice session, the
Red (Armed) and Green (Ready) LEDs will alternately blink in the Talk and VOX
Modes but not during Listen Mode.

Other manuals for Honeywell L5200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell L5200 Series and is the answer not in the manual?

Honeywell L5200 Series Specifications

General IconGeneral
BrandHoneywell
ModelL5200 Series
CategorySecurity System
LanguageEnglish

Related product manuals