LTE-X Series Installation and Setup Guide
– 2 –
Specifications
Dimensions:
4 x 7 x 1.75 inches
Input Voltage:
12VDC (powered via the ECP bus.)
Current:
Standby 25mA, Transmit 250mA
Operating temperature:
–20º to +55ºC, for UL/ULC installations 0ºC to +49ºC
Storage temperature: –40º to +70ºC
Humidity:
0 to 95% relative humidity, non-condensing
(UL installations 0% to 85%; for ULC installations 0% to 93%)
Altitude:
to 10,000 ft. operating, to 40,000 ft. storage
Frequency Bands
LTE
Band 2
LTE
Band 4
LTE
Band 5
LTE
Band 12
LTE
Band 13
WCDMA
Band II
LTE-XV
X
X
X
LTE-XA
X
X
X
X
X
X
LTE-XC
X
X
X
X
X
X
Output Power
LTE, Class 3 23dBm
WCDMA Class 3 24dBm
Data Encryption
The communicator uses 256 bit AES (Rijndael) encryption (which is required for certain government installations). The
AlarmNet-i AES Encryption Software Module Version 1.0 contained in the Honeywell products has NIST approval.
Listings for this approval can be found at https://csrc.nist.gov/Projects/Cryptographic-Algorithm-Validation-
Program/Validation/Validation-List/AES and search for “Certificate number 979.
Remote Services Features
UL
Remote Access has not been evaluated by UL.
Honeywell offers secure web based services that enable users to remotely monitor and control their security system.
These web services enable
users to:
Monitor and control their security system from a website
Receive e-mail and text message notifications of system events
Control the system and receive confirmations using text messages
Monitor and control IP video cameras
Dealers can enroll their customers for "Remote Services" by using the AlarmNet 360 website. Once enabled, the specific
programming fields associated with these features can be programmed into the communications device either remotely
using the AlarmNet 360 website or locally using the 7720P programming tool.
E-mail notification (Multi Mode) is intended as a convenience for the user, and does not replace Central
Station reporting of critical events (alarms, troubles, etc.).
Testing the System
After installation the security system should be tested. Refer to the control panel installation instructions for procedures
to test the entire system.
Compatibility
The communicator functions with any control panel that utilizes a Honeywell ECP bus and supports a communicator.