Global Tab
Start > Programs > Summit > Global tab
The parameters on this panel can only be changed when an Admin is logged in with a password. The current values for the
parameters can be viewed by the general user without requiring a password.
Note: Tap the Commit button to save changes. If the panel is exited before tapping the Commit button,
changes are not saved!
Factory Default Settings
Roam Trigger -65 dBm
Roam Delta 5 dBm
Roam Period
BG: 10 sec.
A: 5 sec.
BG Channel Set Full
DFS Channels Off
Ad Hoc Channel 1
Aggressive Scan On
CCX Features
BG: Off
A: Optimized
WMM Off
Auth Server Type 1
TTLS Inner Method Auto-EAP
PMK Caching Standard
7-13