RLV4300 69-1918EF 7/24/06 3/4
The thermostat has 3 modes of operation:
6.1 Automatic (programmable) Mode
To use the Automatic mode, press the button until
AUTO is selected (outlined) on the screen. The current
period number will appear.
In this mode, the thermostat automatically adjust its
temperature setpoint according to the period of the day
(wake up, leave for work, return home and sleep).
You can program up to 4 periods in a day. You can set 2 different
programs: one for the weekdays (Monday to Friday) and another one
for the weekend (Saturday and Sunday).
The thermostat is preprogrammed with the following schedule:
To temporarily override the current setpoint, set the desired
temperature using the buttons. The new setpoint will be used
until the beginning of the next period.
To modify the schedule:
n Press the button until AUTO is selected.
o Press the button.
Each time you press the button, the thermostat displays one of
the periods in the following order (from left to right):
p Set the start time for the period using the and buttons.
NOTE: To disactivate the period, press the button. Instead
of displaying the start time of the period, the thermostat will dis-
play --:--. During operation, the thermostat will skip over that
period.
q Set the temperature for the period using the buttons.
r Repeat steps 2 to 4 for the remaining periods.
s Press the button to return the thermostat to normal display.
6.2 Manual (hold) Mode
To use this mode, press the button until MAN is
selected (outlined) on the screen. Then, set the desired
temperature using the buttons.
In this mode, any modification to the temperature
setpoint must be done manually.
6.3 Economy Mode
To use the economy mode, press the button until
ECONO is selected (outlined) on the screen. This
mode is ideal for weekend residences as it can be
used as follows: The temperature is kept at an
economy level during most of your absence and is
raised to a comfortable level by your usual arrival. If
you do not show up, the temperature returns to the
economy level until next weekend.
The economy mode has two periods which should be set as follows:
The economy mode should be used as follows:
Place the thermostat in economy mode during your absence.
When you arrive, place the thermostat in automatic mode or in
manual mode before the temperature drops back to the
economy level.
When you leave, switch the thermostat back to economy mode.
To program the two periods of the economy mode:
n Press the button until ECONO is selected.
o Press the button. Period 1 is displayed.
p Set the start day for the period using the button.
q Set the start time using the and buttons.
r Set the temperature for the period using the buttons.
s Press to select period 2.
t Repeat steps 3 to 5 to set the day, time and temperature for
period 2.
u Press to return the thermostat to normal display.
Warning: When the thermostat is reset, all parameters (clock,
configuration and schedules) return to their default settings. If
necessary, reprogram them.
n Press and hold the button.
o Insert a pointed object (e.g., paperclip) through the reset
opening. Remove it when the thermostat’s screen becomes
blank.
p Wait one second and release the button.
s
Modes of Operation
6.
Period Monday to Friday Saturday & Sunday
Start Time Temperature Start Time Temperature
1 Wake 6:00 21°C (70°F) 6:00 21°C (70°F)
2 Leave 8:00 16°C (62°F) -- --
3 Return 18:00 21°C (70°F) -- --
4 Sleep 22:00 16°C (62°F) 22:00 16°C (62°F)
Monday to Friday Saturday and Sunday
MO TU WE TH FR SA SU
12341234
Period Temperature Setting Start Time Setting
1
Set to a comfortable
level.
Set a time where the temperature
starts to rise to reach a comforta-
ble level by the time you arrive.
2
Set to an economy
level.
Set a time where the temperature
starts to drop to an economy level
if you do not show up.
t
Thermostat Reset
7.