4.2.1 705 LEL Flammable gas sensors (cCSAus Approved)
Standard LEL version
The standard LEL sensor is available for use in temperatures up to 80°C (remote mounting
only) and detects gas concentrations up to 100% LEL of a target gas with a resolution in
the region of 1% LEL, depending on the gas being detected. The sensor is available with
¾”NPT thread only. The standard 705 is both CSA and UL approved.
High Temperature LEL version
The high temperature version(UL approved) is available for use in temperatures up to
150°C (remote mounting only) and detects gas concentrations up to 100% LEL of a target
gas with a resolution in the region of 1% LEL, depending on the gas being detected. The
sensor is available with ¾”NPT thread only. The 705 HT is UL approved only.
Details for connecting these sensors with the Sensepoint XCD RFD transmitter are
provided in sections 5 and 6. For more sensor specific details, refer to the Technical
Handbook Part No. 2106M0502 or their individual manual (705 Combustible Gas Sensor
Operating Instructions Part No: 00705M5002)
705 Standard LEL version 705 High Temperature LEL version
705 LEL ammable sensors

Other manuals for Honeywell Sensepoint XCD RFD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Sensepoint XCD RFD and is the answer not in the manual?

Honeywell Sensepoint XCD RFD Specifications

General IconGeneral
BrandHoneywell
ModelSensepoint XCD RFD
CategorySecurity Sensors
LanguageEnglish

Related product manuals