T8611G CHRONOTHERM
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT
68-0165—1
15
5. Press Copy.
NOTE: donE will be displayed for two seconds and
then the normal program display will be
shown.
Setting Temporary Temperatures
Changing Temperature Setting Until the Next
Program Period
Press increase or decrease key until the desired
temperature setpoint is displayed.
NOTE: If or appear under the temperature display, it
means that both the heating and cooling setpoints
are being adjusted. Tapping the key will change both
the heat and cool setpoints by one degree. Press i
after the desired setpoint is reached to check the
setpoints.
M10328
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Copy
6. Repeat steps 2 through 5 for all the days desired.
7. Press Run Program.
Clearing Program Period
NOTE: The thermostat must be in the program mode to use
the clear feature. Go to step 2 if the thermostat is
already in the program mode.
1. Press Wake, Leave, Return or Sleep.
M10329
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Auto
System Fan
Mon
AM
Leave
Set Program
Start Time
Setting
Heat
2. Press Day until the desired day is displayed.
M10330
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Auto
System Fan
AM
Sat
Leave
Set Program
Start Time
Setting
Heat
3. Press Leave, Return or Sleep until the start time and
temperature setting are cleared (approximately 3
seconds).
NOTE: Wake cannot be cleared.
M10331
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Sat
Leave
Set Program
Start Time
Setting
Leave
4. Repeat steps 2 and 3 for all the periods to be cleared.
5. Press Run Program.
M10332
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Wake
Temporary Setting
NOTE: The temporary temperature setting is displayed for
approximately 3 seconds. The setting is canceled
when the next period starts or when Run Program is
pressed.
Changing Temperature Setting Indefinitely
1. Press Hold Temp.
M10333
Time Set Program
System Fan
Run
Program
Hold Temp
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Setting
2. Press increase or decrease key to change the
setting, if desired.
M10334
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Setting
M10335
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Heat/Cool
Settings
Daylight
Time
Copy
Cool
Setting
3. Press Heat/Cool Settings to change between heat and
cool settings.
4. Press increase or decrease key to adjust
temperature settings.
M10336
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Cool
Setting
NOTE: The display changes from the setpoint to the
room temperature after approximately 3
seconds.
5. Press Run Program to cancel the Hold and to return to
the program.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell T8611G Chronotherm IV Deluxe and is the answer not in the manual?

Honeywell T8611G Chronotherm IV Deluxe Specifications

General IconGeneral
BrandHoneywell
ModelT8611G Chronotherm IV Deluxe
CategoryThermostat
LanguageEnglish

Related product manuals