TB7300 SERIES COMMUNICATING FAN COIL THERMOSTATS
3 62-2018—05
1
Thermostats ordered without an occupancy sensor cover can be retrofitted with an occupancy sensor cover later if
needed.
More Information
We recommend downloading the appropriate integration reference document (wireless or BACnet) and if installing
thermostats with occupancy sensor covers, then also downloading the PIR Application Guide before you begin
installation. All documentation is available on http://customer.honeywell.com.
BACnet Integration Manual for TB7200 and TB7300 Series Thermostats (Form No. 63-4524)
Wireless Installation and Integration Reference Guide for TB7200, TB7300, and TB7600 Thermostats
(Form No. 63-4522)
PIR Application Guide for TB7200 and TB7300 Series Thermostats (Form No. 63-4526)
Sensors Product Overview Brochure (Form 63-9285) provides a complete listing of 10K NTC Type II sensors.
INSTALLATION AND WIRING
Mounting Locations
Do not install on an outside wall.
Must be installed away from any heat source.
Should not be installed near an air discharge grill.
Should not be mounted in direct sun radiation.
Nothing must restrain vertical air circulation to the thermostat.
Wall surface must be flat and clean.
IMPORTANT
If replacing an old thermostat, label the wires before removal of the old thermostat.
CAUTION
Electronic controls are static sensitive devices. Discharge yourself properly before manipulation and installing
the thermostat.
Short circuit or wrong wiring may permanently damage the thermostat or the equipment.
Anti-short cycling can be set to 0 minutes for equipment that has an anti-cycling timer. Do not set to 0 unless
the equipment has internal anti-cycling timer or damage to equipment can occur.
All TB7300 Series thermostats are to be used only as operating controls. Whenever a control failure could
lead to personal injury and/or loss of property, it becomes the responsibility of the user to add safety devices
and/or alarm system to protect against such catastrophic failures.
TB-VWG-APP-1014 TB7XXX Series Wireless Communication Card
TB-WALL-1014 Room Sensor 10K NTC Type 2
TB-WALLOVR-1014 Room Sensor with Override 10K NTC Type 2
Product Number Description Outputs
Occupancy
Sensor
1