EasyManuals Logo

Honeywell Xenon 1952H User Manual

Honeywell Xenon 1952H
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #260 background imageLoading...
Page #260 background image
242 Xenon XP User Guide
This response indicates that Codabar Coding Enable (CBRENA) has a range of val-
ues from 0 to 1 (off and on).
Example: What is the default value for Codabar Coding Enable?
Enter: cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: What is the device’s current setting for Codabar Coding Enable?
Enter: cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on.
Example: What are the device’s settings for all Codabar selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. First,
the scanner must be put in Manual Trigger Mode by scanning a Manual Trigger
Mode barcode (page 87), or by sending a serial menu command for triggering
(page 89). Once the scanner is in serial trigger mode, the trigger is activated and
deactivated by sending the following commands:
Activate: SYN T CR
Deactivate: SYN U CR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon 1952H and is the answer not in the manual?

Honeywell Xenon 1952H Specifications

General IconGeneral
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
TypeHandheld bar code reader
Sensor type-
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supportedCode 128, Code 39, U.P.C.
Optical sensor resolution (W x H)1240 x 800 pixels
2D (matrix & stacked) barcodes supportedData Matrix, PDF417, QR Code
Battery life14 h
Charging time4.5 h
Battery capacity2400 mAh
Power source typeBattery
Number of reads per charge50000
Product colorWhite
LED indicatorsYes
Built-in displayNo
Housing materialPlastic
International Protection (IP) codeIP41
Wireless range10 m
Bluetooth version4.2
Operating frequency2400 MHz
Standard interfacesUSB
Connectivity technologyWired & Wireless
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth99 mm
Width64 mm
Height165 mm
Weight220 g