XT Series Personal Gas Detector
16
13. Specification
Maximum Operating Life
24 months from activation, assuming 3-5 minutes of
alarm per day under normal operating conditions*
Sensor Range
CO
0 to 1000 ppm (display: 0-200 ppm)
H
2
S
0 to 100 ppm (display: 0-100 ppm
O
2
0 to 30% v/v (display: 0-25% v/v)
Alarm Setpoints
Level 1 Level 2
CO
35 ppm 100 ppm
H
2
S
10 ppm 15 ppm
O
2
23.5% 19.5%
Calibration
CO/H
2
S
Zero adjustment (optional Span)
O
2
Span adjustment
Shelf Life
12 months: CO/H
2
S
6 months: O
2
Operating Temperature
-4°F to +122°F (-20°C to +50°C)
Humidity
5-95% RH (non-condensing)
Audible Alarm
95db at 4” (95db at 10cm)
Visual Alarm
High intensity red LEDs