XT Series Personal Gas Detector
19
CO SureCell Cross Sensitivity Data
Gas Type
Concentration Applied
(ppm)
Reading
(ppm CO)
Hydrogen Sulfide 25 0
Sulfur Dioxide 50 0.5
Nitrogen Dioxide 800 20
Nitric Oxide 5 8
Chlorine 2 0
Hydrogen 100 20
Ethylene 100 85
Ammonia 100 0
O
2
Cross Sensitivity Data
Gas Type Concentration Applied
Reading
(%v/v O
2
)
Hydrogen 100% -9%
Methane 100% 0
Nitrogen Dioxide 25 ppm 0