3 - 8
Character Activation Timeout
You can set a timeout for the length of time the illumination remains on and attempting to decode bar codes when using
Character Activation Mode. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting
the timeout (from 1-300,000 milliseconds) by scanning digits from the Programming Chart inside the back cover of this
manual, then scanning Save. Default = 30,000 ms.
Character Deactivation Mode
If you have sent a character from the host to trigger the scanner to begin scanning, you can also send a deactivation character
to stop scanning. Scan the following On bar code to use character deactivation, then use Deactivation Character (following) to
select the character you will send from the host to terminate scanning. Default = Off.
Motion Sensor Mode
When the button is pressed for more than 5 seconds, the scanner will go into Virtual Global Shutter mode. Virtual Global Shut-
ter Mode promotes motion tolerance performance and the illumination will flicker. When the button is pressed for 5 seconds
again, the scanner will go into Rolling Shutter Mode. While in Rolling Shutter Mode, the illumination will remain off. Default =
Virtual Global Shutter Mode.
Mobile Phone Read Mode
When the button is quickly pressed, the scanner will go into Mobile Phone Read Mode. In this mode your scanner is optimized
to read bar codes from mobile phone or other LED displays. When the button is quickly pressed again, the scanner will exit
Mobile Phone Read Mode.
IR Trigger Mode
When in IR Trigger mode, the scanner is activated when it “sees” a bar code. After the bar code is read, the scan illumination
will turn off. When in IR Trigger - Mobile Phone mode, your scanner is optimized to read bar codes from mobile phone or other
LED displays.
Character Activation Timeout
IR Trigger Mode (Default)
IR Trigger - Mobile Phone