EasyManua.ls Logo

Honeywell QuantumT MS3580 - User Manual

Honeywell QuantumT MS3580
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
QUESTIONS?
Ask the experts at POSMicro.com.
1.800.241.6264
Live Chat Now
support@POSMicro.com
Monday - Friday 6 AM to 5 PM Pacic Time
BULK DISCOUNTS
FREE SHIPPING*
SE HABLA
ESPAñOL
*Free ground shipping to the continental USA on orders over $100.
For Help Call
1.800.241.6264
Honeywell MS3580
QuantumT Manual
More information available at POSMicro.com

Questions and Answers

  • H
    Hailey WhiteAug 19, 2025
    What to do if Honeywell QuantumT MS3580 powers up but doesn't communicate with host?
    • K
      knightstephanieAug 19, 2025
      If your Honeywell Scanner powers up and scans but doesn't communicate correctly with the host, ensure the baud rate and parity of both the scanner and the host match. Also, verify the cable is connected to the correct com port.
  • F
    fred34Aug 21, 2025
    What to do if Honeywell Scanner powers up but does not scan or beep?
    • B
      Brooke YatesAug 21, 2025
      If your Honeywell Scanner powers up but doesn't scan or beep, check if it has been configured for a character length lock or a minimum length criteria. Verify that the bar code being scanned meets these criteria.
  • H
    Heather TorresAug 23, 2025
    Why Honeywell Scanner powers up but does not beep?
    • I
      imillerAug 25, 2025
      If your Honeywell Scanner powers up but does not beep, it may be because the beeper is disabled. Enable the beeper. Alternatively, no tone may be selected, so select a tone.
  • K
    Kevin PayneAug 26, 2025
    Why Honeywell QuantumT MS3580 Scanner scans the barcode but no data?
    • S
      Samuel BarberAug 26, 2025
      If your Honeywell Scanner scans the bar code but there is no data, ensure that the proper PC type (i.e., AT, PS2, or XT) is selected.
  • P
    Peter MercadoAug 28, 2025
    What to do if Honeywell Scanner scans but data is not correct?
    • M
      Michelle PattonAug 28, 2025
      If your Honeywell Scanner scans but the data is not correct, verify that the correct country code and data formatting are selected, and adjust the intercharacter delay.
  • D
    Douglas FischerAug 30, 2025
    Why Honeywell QuantumT MS3580 beeps at some barcodes and not others?
    • S
      Stephen QuinnAug 30, 2025
      If your Honeywell Scanner beeps at some bar codes but not others of the same symbology, check if check digits are set properly, as the scanner may not be configured correctly for the type of bar code.
  • W
    Wyatt RobinsonSep 1, 2025
    Why Honeywell QuantumT MS3580 Scanner has multiple scans on same symbol?
    • L
      Laura MooreSep 1, 2025
      If your Honeywell Scanner produces multiple scans upon presentation of the same symbol, adjust the same symbol timeout for a longer time increment, as the timeout may be set too short.
  • S
    Stephanie DavisSep 3, 2025
    How to fix Honeywell QuantumT MS3580 not transmitting each character?
    • A
      angeladixonSep 3, 2025
      If your Honeywell Scanner is not transmitting each character, adjust whether the F0 break is transmitted. It may be necessary to try both settings.
  • B
    Barbara EllisSep 5, 2025
    Why Honeywell QuantumT MS3580 is dropping characters?
    • J
      James SanchezSep 6, 2025
      If characters are being dropped by your Honeywell Scanner, add some intercharacter delay to the transmitted output by using the MetroSelect Configuration Guide (MLPN 00-02407).
  • K
    Kirsten ThompsonSep 7, 2025
    Why is Honeywell QuantumT MS3580 Scanner transmitting incorrect data to the host?
    • A
      Anthony ParkerSep 8, 2025
      If the data transmitted from your Honeywell Scanner to the host is incorrect, ensure that the scanner is connected to the proper host port, as the scanner’s data format may not match what the host requires.

Summary

Introduction

Scanner and Accessories

Details the basic kit components and optional accessories available for the MS3580 scanner.

Maintenance

Offers guidance on cleaning and maintaining the MS3580 scanner to ensure optimal performance.

Installation

RS232, RS232 TTL, Light Pen or Laser Emulation

Guides the user through connecting the scanner using RS232, TTL, Light Pen, or Laser emulation interfaces.

RS485

Details the installation procedure for the MS3580 scanner using the RS485 communication interface.

Keyboard Wedge

Explains how to install the scanner for use with a keyboard wedge interface.

Stand-Alone Keyboard

Provides instructions for setting up the scanner in a stand-alone keyboard configuration.

USB

Covers the installation process for connecting the MS3580 scanner via USB.

Scanner Operation

Failure Mode Indicators

Lists the LED and audible indicators that signal scanner malfunctions and their solutions.

Troubleshooting Guide

Design Specifications

Applications and Protocols

Default Settings - Communication Parameters

Configuration Modes

Upgrading the Firmware

Scanner and Cable Terminations

Regulatory Compliance

Safety

Highlights critical safety precautions, particularly regarding laser exposure and proper usage.

Customer Support

Honeywell QuantumT MS3580 Specifications

General IconGeneral
Scan TechnologyLaser
InterfaceUSB, RS-232, Keyboard Wedge
Reading Distance40 mm - 216 mm
Weight170 g
Power Supply5 VDC ± 0.25 V
Light Source650 nm visible laser diode
Decode Capability1D barcodes
Depth of Field40 mm - 216 mm (1.5" - 8.5") for 0.33 mm (13 mil) bar codes
Field of View42°
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-40°C to 60°C (-40°F to 140°F)
Humidity5% to 95% (non-condensing)
Voltage Range5 VDC ± 0.25 V
Supported SymbologiesUPC/EAN, Code 39, Code 128, RSS

Related product manuals