Indesit Company
29 of 36
Service Manual UK English
SMARTCARD PROGRAMMING PROCEDURE - FLOWCHART
DISCONNECT(unplug)THEAPPLIANCEFROMTHEELECTRICALSUPPLY(grid)
INSERTAVALIDSMARTCARD,RELATINGTOTHEMODEL&MAINPOWER
MODULE(board)TOBEPROGRAMMED,INTOTHESMARTCARDREADER
INSERTTHESMARTCARDREADERINTOEITHERTHESERIALPORTOFTHE
POWERMODULE(BOARD)ORINTOTHELOWENDADAPTOR(Version2007)
CONNECTIONISVERIFIED(OK)DOWNLOADNOWINPROGRESS
THEPOWERMODULEISNOWPROGRAMMED.
DISCONNECT(unplug)THEAPPLIANCEFROMTHEELECTRICALSUPPLY(grid)
REMOVETHESMARTCARDREADER
(DISCONNECTTHELOWENDADAPTORWHEREUSED)
IFTHERED LEDISFLASHING
x COMMUNICATIONPROBLEM
x SMARTCARDINVALID/ERASED
DISCONNECT(unplug)THEAPPLIANCEFROMTHE
ELECTRICALSUPPLY(grid)
DOWNLOADOK
THESMARTCARDCONTENTWILLBE
AUTOMATICALLYERASED
IFTHE RED LEDISSTATIC(fixed):
x DOWNLOADHASFAILED(KO)
IFTHEDOWNLOADFAILEDTHESMARTCARD
WOULDNOTHAVEBEENERASED
DISCONNECTTHESMARTCARDREADER
FROMTHEAPPLIANCEANDTHE
SMARTCARDFROMTHESMARTCARD
READER
RESOLVETHEPROBLEM:
FURTHERDIAGNOSTICSMAYBEREQUIRED
ONTHEAPPLIANCE
NO
YES
NO
YES
ISTHE
GREENLED
FLASHING?
ISTHE
GREENLED
STATIC?
START
DISCONNECTTHESMARTCARDREADERFROMTHE
APPLIANCEANDTHESMARTCARDFROMTHE
SMARTCARDREADERANDACTIONBELOW:
IftheREDLEDwasflashingSLOWLY,anda
smartcardwasinserted,checkforthefollowing:
x Invalid/erasedsmartcard(previouslyused)
Discardtheinvalidsmartcard,
x Incorrectlyinsertedsmartcard,
(checkorientationof
the
smartcardchip)
x Poorconnectionbetweenthesmartcardand
smartcardreader.
IftheREDLEDwasflashingRAPIDLY,checkforthe
following:
x Ensureasmartcardwasinsertedintothe
smartcardreader,
x Ensurethesmart cardwasfullyinserted?