EasyManua.ls Logo

Hoveround MPV5 - Appendices; Chapter 9 Appendices; Appendix A Programmable Parameters

Hoveround MPV5
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9
Appendices
D82008753R 10/15 Chapter 9 51
Appendix A:
Programmable Parameters
The controller used on your power wheelchair is programmable for basic
functions. It requires a programmer to make changes. Any changes must
be made by a qualified technician only.
The following chart indicates the standard program values of the
factory settings. Refer to the appropriate section depending on the
style of control system on your chair. Any subsequent change of the
programmed values should be recorded and saved for future reference.
Program Settings
CONTROLLER VSI VSI VSI PSL VSI PSL New VSI
Chair serial # 5500000 + 5500000 + 5800000 +
Acceleration 20 30 20 30 30
Deceleration 40 50 50 50 50
Forward Speed Max 100 85 100 90 85
Forward Speed Min 10 30 10 30 30
Turn Speed Max 15 17 18 18 17
Turn Speed Min 10 17 18 18 17
Reverse Speed Max 55 55 55 55 55
Reverse Speed Min 10 35 10 35 35
Turn Acceleration 30 25 30 25 25
Turn Deceleration 40 65 40 65 65
Load Comp 85 125 85 125 125