Chapter 11
Appendices
D82007778Q 09/15 Chapter 11 51
Appendix A:
Programmable Parameters
The controller used on your power wheelchair is programmable for basic
functions. It requires a programmer to make changes. Any changes must
be made by a qualified technician only.
The following chart indicates the standard program values of the factory
settings. Refer to the appropriate section depending on the style of con-
trol system on your chair. Any subsequent change of the programmed
values should be recorded and saved for future reference.
Program Settings
TEK FWD TEK RWD TEK XHD TEK HD-6 TEK GT
Program Settings VSI VR2 ALL VSI / VR2 VR2 Pilot+ VR2
Forward Speed Max 85 75 100 85 70 100 100
Forward Speed Min 10 20 10 10 10 25 20
Forward Acceleration 30 20 30 30 30 20 30
Forward Deceleration 50 65 50 50 50 50 70
Reverse Speed Max 55 50 55 50 50 55 50
Reverse Speed Min 10 20 10 10 20 10 20
Turning Speed Max 15 15 20 15 15 25 17
Turning Speed Min 10 10 10 10 10 25 10
Turning Acceleration 10 10 30 20 20 5 15
Turning Deceleration 20 70 20 20 50 5 70