'Label42'" from the session "2008/07/01-2", using the device "DEV1" to read
the source objects and the device "DEV2" copy the objects, run:
omniobjcopy -filesystem system1.company.com:/ 'Label42'
-session 2008/07/01-2 -sourcedevice 'DEV1' -targetdevice
'DEV2' -full
3. To immediately start a post-backup object copy specification named "post_BU1"
for the session "2008/08/03-1", use:
omniobjcopy -copylist post_BU1 -postbackup -session
2008/08/03-1
4. To immediately start a scheduled object copy specification named "CopySpec",
use:
omniobjcopy -copylist CopySpec -scheduled
5. To restart a failed post-backup object copy specification "2009/03/16–9",
use:
omniobjcopy -restart "2009/03/16–9"
SEE ALSO
omnib(1), omnikeymigrate(1M), omnikeytool(1M), omniobjconsolidate(1),
omniobjverify(1), omnir(1)