The -seq option sets the sequence number for the new DCBF directory. Each
DCBF directory has a certain position which determines when DCBF will be
created in the DCBF directory. The first DCBF directory to be used for DCBF has
the lowest sequence number. The order of the DCBF directories to be used is
determined by the sequence number. Sequence is used only if the
DCDirAllocation option in the Data Protector global options file is set to 0.
The Data Protector global options file resides on the Cell Manager in the directory
Data_Protector_program_data\Config\Server\options (Windows
Server 2008), Data_Protector_home\Config\Server\options (other
Windows systems) or/etc/opt/omni/server/options (UNIX systems). If
the -seq option is not specified, 0 will be used.
-modify_dcdir Pathname [-maxsize Size_MB]
[-maxfiles NumberOfFiles] [-spacelow Size_MB] [-seq
Number]
Modifies a DCBF directory under the specified path.
The -maxsize option modifies the amount of disk space that can be used for
DCBF in this directory. When the modified size is reached, Data Protector stops
creating new DCBF in this directory. If this option is not specified, then the default
size of 16384 MB is used.
When you increase the maximum size, you should also adjust the free disk space
needed for a DCBF binary file (10 to 15% of the maximum size is recommended)
by using -spacelow option.
The -maxfiles option modifies the number of DCBF that can be stored in the
directory. When the modified number is reached, Data Protector stops creating
new DCBF in this directory. If this option is not specified, then the default value
of 500 files is used. Only values under 10000 are valid.
The -spacelow option modifies the actual free disk space needed for a DCBF
binary file to be created. When the free space falls below the modified free disk
space, Data Protector stops creating new DCBF in this directory. If this option is
not specified, the default of 2048 MB is used.
The -seq option modifies the sequence of a DCBF directory. Each DCBF directory
has a certain position which determines when DCBF will be created in the DCBF
directory. Sequence is used only if the DCDirAllocation option in the Data
Protector global options file is set to 0. The Data Protector global options file
resides on the Cell Manager in the directory
Data_Protector_program_data\Config\Server\options (Windows
Server 2008), Data_Protector_home\Config\Server\options (other
Windows systems) or/etc/opt/omni/server/options (UNIX systems). If
the -seq option is not specified, 0 will be used.
-remove_dcdir Pathname
Command line interface reference 321

Table of Contents

Other manuals for HP Data Protector A.06.11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Data Protector A.06.11 and is the answer not in the manual?

HP Data Protector A.06.11 Specifications

General IconGeneral
BrandHP
ModelData Protector A.06.11
CategorySoftware
LanguageEnglish

Related product manuals