Accessing the switch 16
SNMPv2 trap host configuration
The SNMPv2 trap host configuration is similar to the SNMPv1 trap host configuration.
Wherever you specify the model, specify snmpv2 instead of snmpv1.
c/sys/ssnmp/snmpv3/usm 10 (Configure user named “v2trap”)
name "v2trap"
/c/sys/ssnmp/snmpv3/access 10 (Define access group to view SNMPv2 traps)
name "v2trap"
model snmpv2
nview "iso"
/c/sys/ssnmp/snmpv3/group 10 (Assign user to the access group)
model snmpv2
uname v2trap
gname v2trap
/c/sys/ssnmp/snmpv3/notify 10 (Assign user to the notify table)
name v2trap
tag v2trap
/c/sys/ssnmp/snmpv3/taddr 10 (Define an IP address to send traps)
name v2trap
addr 47.81.25.66
taglist v2trap
pname v2param
/c/sys/ssnmp/snmpv3/tparam 10 (Specify SNMPv2 traps to send)
name v2param
mpmodel snmpv2c
uname v2trap
model snmpv2
/c/sys/ssnmp/snmpv3/comm 10 (Define the community string)
index v2trap
name public
uname v2trap
SNMPv3 trap host configuration
To configure a user for SNMPv3 traps, you can choose to send the traps with both privacy and authentication, with
authentication only, or without privacy or authentication. Use the following commands to configure the access table:
/c/sys/ssnmp/snmpv3/access <x>/level
/c/sys/ssnmp/snmpv3/tparam <x>
Configure the user in the user table to match the configuration of the access table.
It is not necessary to configure the community table for SNMPv3 traps because the community string is not used by
SNMPv3.
The following example shows how to configure a SNMPv3 user v3trap with authentication only:
/c/sys/ssnmp/snmpv3/usm 11 (Configure user named “v3trap”)
name "v3trap"
auth md5
authpw v3trap
/c/sys/ssnmp/snmpv3/access 11 (Define access group to view SNMPv3 traps)
name "v3trap"
level authNoPriv
nview "iso"
/c/sys/ssnmp/snmpv3/group 11 (Assign user to the access group)
uname v3trap
gname v3trap
/c/sys/ssnmp/snmpv3/notify 11 (Assign user to the notify table)
name v3trap
tag v3trap
/c/sys/ssnmp/snmpv3/taddr 11 (Define an IP address to send traps)
name v3trap
addr 47.81.25.66
taglist v3trap
pname v3param
/c/sys/ssnmp/snmpv3/tparam 11 (Specify SNMPv3 traps to send)
name v3param
uname v3trap
level authNoPriv (Set the authentication level)
For more information on using SNMP, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command
Reference Guide.

Table of Contents

Other manuals for HP GbE2c - Blc Layer 2/3 Fiber SFP Option

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP GbE2c - Blc Layer 2/3 Fiber SFP Option and is the answer not in the manual?

HP GbE2c - Blc Layer 2/3 Fiber SFP Option Specifications

General IconGeneral
BrandHP
ModelGbE2c - Blc Layer 2/3 Fiber SFP Option
CategorySwitch
LanguageEnglish

Related product manuals