HP P2000 G3 MSA System Event Descriptions Reference Guide 11
7
Error In a testing environment, a controller diagnostic failed and reports a product-specific diagnostic code.
Recommended actions
Perform failure analysis.
8
Warning The indicated disk in the indicated vdisk failed and the vdisk changed to a status of critical (CRIT) or offline
(OFFL). If a spare is present the controller automatically uses the spare to reconstruct the vdisk. Subsequent
events indicate the changes which happen to the vdisk.
Recommended actions
If the indicated disk failed because of excessive media errors, imminent disk failure, possible hardware
failure, or a disk that is not supported, replace the disk.
If the indicated disk failed because a user forced the disk out of the vdisk, or for an unknown reason,
see Troubleshooting steps for leftover disk drives on page 60.
If the indicated disk failed because a previously detected disk is no longer present, reinsert the disk or insert a
replacement disk. If the disk then has a status of leftover (LEFTOVR), see Troubleshooting steps for leftover disk
drives on page 60.
No action is required if the condition that caused the indicated disk failure is that RAID-6 initialization
failed. This disk is now a spare for the vdisk and reconstruction will start.
When the problem is resolved, event 9 is logged.
9
Info. The indicated spare disk has been used in the indicated critical vdisk to bring it back to a fault-tolerant
status.
Vdisk reconstruction starts automatically. This event indicates that a problem reported by event 8 is
resolved.
Recommended actions
No action is required.
16
Info. The indicated disk has been designated a global spare.
Recommended actions
No action is required.
18
Warning Vdisk reconstruction failed.
Recommended actions
Determine whether the reconstruction failed due to a disk failure and whether replacing that disk will
enable reconstruction to start and complete without further errors. To determine this, look for another
event logged at approximately the same time that indicates a disk failure such as event 55, 58, or 412.
Follow the recommended action for that event.
Info. Vdisk reconstruction succeeded.
Recommended actions
No action is required.

Other manuals for HP P2000 G3 MSA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 MSA and is the answer not in the manual?

HP P2000 G3 MSA Specifications

General IconGeneral
ModelHP P2000 G3 MSA
Form Factor2U
Drive TypesSAS, SATA
ControllersDual controllers
Host InterfaceSAS, iSCSI, Fibre Channel
RAID Levels0, 1, 5, 6, 10
ManagementWeb-based, CLI
Cache Memory2 GB per controller

Related product manuals