16 Event descriptions
58
Error A disk drive detected a serious error, such as a parity error or disk hardware failure.
Recommended actions
Replace the failed disk.
Warning A disk drive reset itself due to an internal logic error.
Recommended actions
The first time this event is logged with Warning severity, if the indicated disk is not running the latest
firmware, update the disk firmware.
If this event is logged with Warning severity for the same disk more than five times in one week, and
the indicated disk is running the latest firmware, replace the disk.
Info. A disk drive reported an event.
Recommended actions
No action is required.
59
Warning The controller detected a parity event while communicating with the indicated SCSI device. The event was
detected by the controller, not the disk.
Recommended actions
If the event indicates that a disk or an expansion module is bad, replace the indicated device.
Info. The controller detected a non-parity error while communicating with the indicated SCSI device. The error
was detected by the controller, not the disk.
Recommended actions
No action is required.
61
Error The controller reset the indicated disk channel to recover from a communication error. This event is logged
to identify an error trend over time.
Recommended actions
If the controller recovers, no action is required.
View other logged events to determine other action to take.
62
Warning The indicated global or dedicated spare disk has failed.
Recommended actions
Replace the failed disk.
If the failed disk was a global spare, configure the new disk as a global spare.
If the failed disk was a dedicated spare, configure the new disk as a dedicated spare for the same
vdisk.
65
Error An uncorrectable ECC error occurred on the buffer memory on startup.
The controller is automatically restarted and its cache data are restored from the partner controller’s cache.
Recommended actions
Replace the controller module that logged this event.