HP P2000 G3 MSA System Event Descriptions Reference Guide 17
67
Info. The controller has identified a new disk or group of disks that constitute a vdisk and has taken ownership
of the vdisk. This can happen when disks containing data have been inserted from another enclosure. This
event only applies to non-Active-Active controllers.
Recommended actions
You may need to clear the disks metadata if you want to reuse them in one or more new vdisks.
68
Info. The controller that logged this event is shut down, or both controllers are shut down.
Recommended actions
No action is required.
71
Info. The controller has started or completed failing over.
Recommended actions
No action is required.
72
Info. After failover, recovery has either started or completed.
Recommended actions
No action is required.
73
Info. The two controllers are communicating with each other and cache redundancy is enabled.
Recommended actions
No action is required.
74
Info. The FC loop ID for the indicated vdisk was changed to be consistent with the IDs of other vdisks. This can
occur when disks containing a vdisk are inserted from an enclosure having a different FC loop ID.
This event is also logged by the new owning controller after vdisk ownership is changed.
Recommended actions
No action is required.
75
Info. The indicated volume’s LUN (logical unit number) has been unassigned because it conflicts with LUNs
assigned to other volumes. This can happen when disks containing data for a mapped volume have been
moved from one storage system to another.
Recommended actions
If you want hosts to access the volume data on the inserted disks, map the volume with a different LUN.
76
Info. The controller is using default configuration settings. This event occurs on the first power up, and might
occur after a firmware update.
Recommended actions
If you have just performed a firmware update and your system requires special configuration settings,
you must make those configuration changes before your system will operate as before.

Other manuals for HP P2000 G3 MSA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 MSA and is the answer not in the manual?

HP P2000 G3 MSA Specifications

General IconGeneral
ModelHP P2000 G3 MSA
Form Factor2U
Drive TypesSAS, SATA
ControllersDual controllers
Host InterfaceSAS, iSCSI, Fibre Channel
RAID Levels0, 1, 5, 6, 10
ManagementWeb-based, CLI
Cache Memory2 GB per controller

Related product manuals