20 Event descriptions
96
Info. Pending configuration changes that take effect at startup were ignored because customer data might be
present in cache.
Recommended actions
If the requested configuration changes did not occur, make the changes again and then use a
user-interface command to shut down or restart the controller.
103
Info. The name has been changed for the indicated volume.
Recommended actions
No action is required.
104
Info. The size has been changed for the indicated volume.
Recommended actions
No action is required.
105
Info. The default LUN for changed for the indicated volume has changed.
Recommended actions
No action is required.
106
Info. The indicated volume has been added to the indicated vdisk.
Recommended actions
No action is required.
107
Error The controller detected a serious error. In a single-controller configuration, the controller will restart
automatically. In an Active-Active configuration, the partner controller will kill the controller that
experienced the error.
Recommended actions
See “Resources for diagnosing and resolving problems” in the SMU help for the System Events panel,
or the CLI help for the show events command.
108
Info. The indicated volume has been deleted from the indicated vdisk.
Recommended actions
No action is required.
109
Info. The statistics for the indicated volume have been reset.
Recommended actions
No action is required.

Other manuals for HP P2000 G3 MSA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 MSA and is the answer not in the manual?

HP P2000 G3 MSA Specifications

General IconGeneral
ModelHP P2000 G3 MSA
Form Factor2U
Drive TypesSAS, SATA
ControllersDual controllers
Host InterfaceSAS, iSCSI, Fibre Channel
RAID Levels0, 1, 5, 6, 10
ManagementWeb-based, CLI
Cache Memory2 GB per controller