EasyManuals Logo

HP P2000 G3 MSA User Manual

HP P2000 G3 MSA
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
HP P2000 G3 MSA System Event Descriptions Reference Guide 21
11 0
Info. Ownership of the indicated vdisk has been given to the other controller.
Recommended actions
No action is required.
111
Info. The link for the indicated host port is up.
This event indicates that a problem reported by event 112 is resolved. For a system with FC ports, this event
also appears after loop initialization.
Recommended actions
No action is required.
11 2
Warning The link for the indicated host port has unexpectedly gone down.
Recommended actions
Look for corresponding event 111 and monitor excessive transitions indicating a host-connectivity or
switch problem. If this event occurs more than 8 times per hour, it should be investigated.
This event is probably caused by equipment outside of the storage system, such as faulty cabling or a
faulty switch.
If the problem is not outside of the storage system, replace the controller module that logged this event.
11 2
Info. The link for the indicated host port has gone down because the controller is starting up.
Recommended actions
No action is required.
114
Info. The link for the indicated disk-channel port is down. Note that events 114 and 211 are logged whenever a
user-requested rescan occurs and do not indicate an error.
Recommended actions
Look for corresponding event 211 and monitor excessive transitions indicating disk problems. If more
than 8 transitions occur per hour, see “Resources for diagnosing and resolving problems” in the SMU
help for the System Events panel, or the CLI help for the show events command.
116
Error After a recovery, the partner controller was killed while mirroring write-back cache data to the current
controller that logged this event. The controller that logged this event restarted to avoid losing the data in
the partner controller’s cache, but if the other controller does not restart successfully, the data will be lost.
Recommended actions
To determine if data might have been lost, check whether this event was immediately followed by event
56, closely followed by event 71; the failover indicates that the restart did not succeed.
118
Info. Cache parameters have been changed for the indicated volume.
Recommended actions
No action is required.

Other manuals for HP P2000 G3 MSA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 MSA and is the answer not in the manual?

HP P2000 G3 MSA Specifications

General IconGeneral
ModelHP P2000 G3 MSA
Form Factor2U
Drive TypesSAS, SATA
ControllersDual controllers
Host InterfaceSAS, iSCSI, Fibre Channel
RAID Levels0, 1, 5, 6, 10
ManagementWeb-based, CLI
Cache Memory2 GB per controller

Related product manuals