RADIUS Authentication and Accounting
Configuring RADIUS Accounting
Note that there is no time span associated with using the system option. It
simply causes the switch to transmit whatever accounting data it cur-
rently has when one of the above events occurs.
Network: Use Network if you want to collect accounting information
on 802.1X port-based-access users connected to the physical ports on
the switch to access the network. (See also
“Accounting Services” on
page 4.)
Web or MAC: You can also use Web or MAC to collect accounting
information.
Determine how you want the switch to send accounting data to a RADIUS
server:
Start-Stop:
Send a start record accounting notice at the beginning of the account-
ing session and a stop record notice at the end of the session. Both
notices include the latest data the switch has collected for the
requested accounting type (Network, Exec, or System).
Do not wait for an acknowledgement.
The system option (page 6-25) ignores start-stop because the switch sends
the accumulated data only when there is a reboot, reload, or accounting
on/off event.
Stop-Only:
Send a stop record accounting notice at the end of the accounting
session. The notice includes the latest data the switch has collected
for the requested accounting type (Network, Exec, or System).
Do not wait for an acknowledgment.
The system option (page 6-25) always delivers stop-only operation because
the switch sends the accumulated data only when there is a reboot, reload,
or accounting on/off event.
Syntax: [no] aaa accounting < exec | network | system > < start-stop | stop-only >
radius
Configures RADIUS accounting type and how data will be
sent to the RADIUS server.
6-26

Table of Contents

Other manuals for HP ProCurve 5412ZL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5412ZL and is the answer not in the manual?

HP ProCurve 5412ZL Specifications

General IconGeneral
Input Voltage100-240 VAC
Jumbo Frame SupportYes
LayerLayer 3
Port Type10/100/1000Base-T, SFP
ManagementCLI, Web, SNMP

Related product manuals