B-7
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Switch Ports and Network
Cables
Note HP Auto-MDIX was developed and shared with the IEEE for the development
of the IEEE 802.3ab standard. HP Auto-MDIX and the IEEE 802.3ab Auto MDI/
MDI-X feature are completely compatible.
If you connect a Series 5400zl Switch twisted-pair port to another switch or
hub, which typically have MDI-X ports, the Series 5400zl Switch port automat-
ically operates as an MDI port. If you connect it to an end node, such as a
server or PC, which typically have MDI ports, the Series 5400zl Switch port
operates as an MDI-X port. In all cases, you can use standard straight through
cables.
If you happen to use a correctly wired crossover cable, though, the switch will
still be able to automatically detect the MDI/MDI-X operation and link
correctly to the connected device.
If the port configuration is changed to any of the fixed configurations
though, for example 100 Mbps/full duplex, the port operates as MDI-X only
and the correct cable type must be used. In general, for connections to MDI
ports, such as end nodes, use a straight-through cable; for connections to MDI-
X ports, such as on hubs and other switches, use a crossover cable.
Other Wiring Rules:
All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-B (not USOC). See the Pin Assignment tables
below the cable illustrations later in this appendix for a listing of the
signals used on each pin.
For 1000Base-T connections, all four pairs of wires in the cable must be
available for data transmission. See “Note on 1000Base-T Cable Require-
ments” on page B-2 for more information on 1000Base-T cabling.
For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
100-ohm differential unshielded twisted-pair (UTP) or shielded twisted-
pair (STP) cable, as supported by the IEEE 802.3 10Base-T standard.
For 100 Mbps connections to the ports, use Category 5 100-ohm differen-
tial UTP or STP cable only, as supported by the IEEE 802.3u 100Base-TX
standard.
For 1000 Mbps connections, Category 5 or better 100-ohm differential UTP
or STP cable only, as supported by the IEEE 802.3ab 1000Base-T standard;
Category 5e or better is recommended.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve Series 5400zl and is the answer not in the manual?

HP ProCurve Series 5400zl Specifications

General IconGeneral
BrandHP
ModelProCurve Series 5400zl
CategorySwitch
LanguageEnglish

Related product manuals