Removal and replacement procedures 73
Figure 61 System fan connections
Device number Connector
System fan 1 P23 on the system board
System fan 2 P25 on the system board
System fan 3 P21 on the system board
System fan 4 P19 on the system board
System fan 5 P18 on the system board
System fan 6 P24 on the system board
System fans 1 to 5 are for the memory modules and processors, while system fan 6 is for the PCI slots and
system chipsets.
A new system fan can be installed to allow the server to operate properly in case a default system fan
becomes defective.
To remove the system fan:
1. Disconnect the fan cable from its corresponding board connector.
2. Release the fan cable from the cable clip.
3. Lift the system fan away from the chassis.