QuickSpecs
HPE ProLiant DL360 Generation9 (Gen9)
Technical Specifications
Page 58
System Unit
Dimensions
8 SFF and 10 SFF 1.7 x 17.1 x 27.5 inches (4.32 x 43.47 x 69.85 cm)
4 LFF - 1.7 x 17.1 x 29.5 inches (4.32 x 43.46 x 75.0 cm)
Weight
(approximate)
Maximum:
(all hard drives, power
supply, and processor
installed)
8 SFF CTO Server 33.3 lb. (15.31 kg)
NOTE: Includes 2 SFF Option for a total of 10
SFF HDD.
4 LFF CTO Server 37 lb. (16.78kg)
Minimum:
(one hard drive, power
supply, and processor
installed)
8SFF CTO Server 27 lb. (12.25 kg)
4 LFF CTO Server 30.36 lb. (13.77 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
200 to 240 VAC
BTU Rating
Maximum
For 800W Power Supply: 3207 BTU/hr (at 100
VAC), 3071 BTU/hr (at 200 VAC), 3112 BTU/hr
(at 240 VAC) for China Only
For 500W Power Supply: 1979 BTU/hr (at 100
VAC), 1911 BTU/hr (at 200 VAC), 1965 BTU/hr
(at 240 VAC) for China Only
Power Supply Output
(per power supply)
Rated Steady-State
Power
For 1400W Power Supply: 1400W (at 240 VAC),
1400W (at 240 VAC)
For 800W Power Supply: 800W (at 100 VAC),
800W (at 240 VAC), 800W (at 240 VAC) input
for China only
For 500W Power Supply: 500W (at 100 VAC),
500W (at 240 VAC), 500W (at 240 VAC) input
for China only
Maximum Peak Power
For 1400W Power Supply: 1400W (at 200 to 240
1VAC), 1400W (at 240 VAC) input for China only
For 800W Power Supply: 800W (at 100 to 127
VAC), 800W (at 200 to 240 1VAC), 800W (at
240 VAC) input for China only
For 500W Power Supply: 500W (at 100 to 127
VAC), 500W (at 200 to 240 VAC), 500W (at 240
VAC) input for China only
System Inlet Temperature
Standard Operating
Support
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20°C/hr
(36°F/hr). The upper limit and rate of change
may be limited by the type and number of options
installed.
NOTE: System performance during standard
operating support may be reduced if operating
with a fan fault or above 30°C (86°F).
Extended Ambient
Operating Support
For approved hardware configurations, the
supported system inlet range is extended to be:
5° to
10°C (41° to 50°F) and 35° to 40°C (95° to
104°F) at sea level with an altitude derating of