HP ProLiant DL380 Generation9 (Gen9)
c04375627 – DA – 15034 North America — Version 7 — February 17, 2015
SFF Drives: 3.44 x 17.54 x 26.75 in (8.73 x 44.55 x 67.94 cm)
LFF Drives: 3.44 x 17.54 x 28.75 in (8.73 x 44.55 x 73.02 cm)
NOTE: Dimensions without Bezel.
(Minimum - 8SFF
model with 1xSFF
HDD and 7 HDD
blanks, 1x processor,
1x power supply
(plus blank), 1x
Flexible Smart Array,
1x Riser installed)
(Maximum - 12 LFF
hard drives (No rear
drives), 2x
processors, 2x power
supplies, 1x Flexible
Smart Array, 2x
Risers installed)
For 800W Power Supply: 3207 BTU/hr (at 100 VAC), 3071 BTU/hr (at
200 VAC), 3112 BTU/hr (at 240 VAC) for China Only
For 500W Power Supply: 1979 BTU/hr (at 100 VAC), 1911 BTU/hr (at
200 VAC), 1965 BTU/hr (at 240 VAC) for China Only
For 1400W Power Supply: 1400W (at 100 VAC), 1400W (at 240 VAC),
1400W (at 240 VAC)
For 800W Power Supply: 800W (at 100 VAC), 800W (at 240 VAC),
800W (at 240 VAC) input for China only
For 500W Power Supply: 500W (at 100 VAC), 500W (at 240 VAC),
500W (at 240 VAC) input for China only
For 1400W Power Supply: 1400W (at 100 to 127 VAC), 1400W (at 200
to 240 1VAC), 1400W (at 240 VAC) input for China only
For 800W Power Supply: 800W (at 100 to 127 VAC), 800W (at 200 to
240 1VAC), 800W (at 240 VAC) input for China only
For 500W Power Supply: 500W (at 100 to 127 VAC), 500W (at 200 to
240 VAC), 500W (at 240 VAC) input for China only
Standard Operating
Support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The upper limit
and rate of change may be limited by the type and number of options
installed. System performance during standard operating support
may be reduced if operating with a fan fault or above 30°C (86°F).
Extended Ambient
Operating Support
For approved hardware configurations, the supported system inlet
range is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C (95° to
104°F) at sea level with an altitude derating of 1.0°C per every 175 m
(1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050
m (10,000 ft). The approved hardware configurations for this system
are listed at the URL: http://www.hp.com/servers/Ashrae
For approved hardware configurations, the supported system inlet
range is extended to be: 40° to 45°C (104° to 113°F) at sea level with an
altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft)
above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft). The
approved hardware configurations for this system are listed at the
URL: http://www.hp.com/servers/Ashrae