EasyManuals Logo

HP R1500 G2 User Manual

HP R1500 G2
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Unit Dimensions
Unit DimensionsUnit Dimensions
Unit Dimensions
17.5 x 1.75 x 23.0 in (44.45 x 4.44 x 58.42 cm)
Shipping Dimensions
Shipping DimensionsShipping Dimensions
Shipping Dimensions
32 x 11.5 x 26.75 in (81.28 x 29.21 x 67.95 cm)
Unit Weight
Unit WeightUnit Weight
Unit Weight
50.5 lb (22.9 kg)
Shipping Weight
Shipping WeightShipping Weight
Shipping Weight
76 lb (34.5 kg)
Electrical Input
Electrical InputElectrical Input
Electrical Input
Voltage Range
Voltage RangeVoltage Range
Voltage Range
± 20% of nominal100, 120 and 230V models. See Model Matrix for
nominal and user selectable voltage settings via the rear panel dip switch
Frequency
FrequencyFrequency
Frequency
50/60 Hz ± 5Hz (auto sensing)
Input Plug
Input PlugInput Plug
Input Plug
See Model Matrix
Online Efficiency
Online EfficiencyOnline Efficiency
Online Efficiency
95%
Surge Suppression
Surge SuppressionSurge Suppression
Surge Suppression
High Energy 6500A peak
Electrical Output
Electrical OutputElectrical Output
Electrical Output
Online Regulation
Online RegulationOnline Regulation
Online Regulation
-10% to +6% of nominal voltage
On battery Regulation
On battery RegulationOn battery Regulation
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Voltage Wave FormVoltage Wave Form
Voltage Wave Form
Sine wave
Connections
ConnectionsConnections
Connections
See Model Selection Matrix; divided into 2 Load Segments
Output Protection
Output ProtectionOutput Protection
Output Protection
Firmware overload sensing and control, customer supplied facility input
circuit breaker, and re-settable rear panel circuit breaker on the INTL HV
AF418A
Battery
BatteryBattery
Battery
Type
TypeType
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Backup Time
Backup TimeBackup Time
Backup Time
See Backup Times Chart
Recharge Time
Recharge TimeRecharge Time
Recharge Time
<3 hours to 90% usable capacity; <24 hours for complete recharge
Voltage
VoltageVoltage
Voltage
36V Battery String
Communications
CommunicationsCommunications
Communications
Ports
PortsPorts
Ports
Standard DB-9 port (ships with communication cable)
USB port (ships with communication cable)
Option Slot
Option SlotOption Slot
Option Slot
One
Option Cards
Option CardsOption Cards
Option Cards
HP UPS Management Module
LED Indicators
LED IndicatorsLED Indicators
LED Indicators
LED display integrated into the front panel
Software
SoftwareSoftware
Software
HP Power Manager management software
Environmental and Safety
Environmental and SafetyEnvironmental and Safety
Environmental and Safety
Operating Temperature
Operating TemperatureOperating Temperature
Operating Temperature
50° to 104° F (10° to 40° C)
Transit Temperature
Transit TemperatureTransit Temperature
Transit Temperature
-5° to 131° F (-15° to 55° C)
Storage Temperature
Storage TemperatureStorage Temperature
Storage Temperature
-15° to 55° F (-26° to 13° C )
Humidity
HumidityHumidity
Humidity
(Operation)
5% to 95%
Humidity
HumidityHumidity
Humidity
(Non-operating)
5% to 95%
Operating Altitude
Operating AltitudeOperating Altitude
Operating Altitude
3000 m <35 d C; 1500 m 36 - 40 d C
Storage Altitude
Storage AltitudeStorage Altitude
Storage Altitude
<40db in normal operation; <45db while on inverter
Audible Noise
Audible NoiseAudible Noise
Audible Noise
<46db (at 1m from surface of unit)
Safety Markings
Safety MarkingsSafety Markings
Safety Markings
UL/cUL ICES, GS, GOST, EK
Safety Certifications
Safety CertificationsSafety Certifications
Safety Certifications
UL1778; UL6950, CSA22.2 No.107.1,No.107.2,No.950; CB Bulletin
No.86AI; EN50091-1; EN60950;
EMC Markings
EMC MarkingsEMC Markings
EMC Markings
FCC-A; CISPR 22; VCCI-A; CE, BSMI, C-TICK
Emissions
EmissionsEmissions
Emissions
FCC CFR 47, Part 15 Class A, EN50091-2
Immunity
ImmunityImmunity
Immunity
IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5
QuickSpecs
HP R1500 G2 UPS
HP R1500 G2 UPSHP R1500 G2 UPS
HP R1500 G2 UPS
Technical Specifications
DA - 12507 North America — Version 10 — June 20, 2011
Page 8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP R1500 G2 and is the answer not in the manual?

HP R1500 G2 Specifications

General IconGeneral
Interface PortUSB
Input Frequency50/60 Hz
Output Frequency50/60 Hz
Output Power Capacity1500 VA
Battery TypeSealed Lead-Acid
Transfer Time4 ms

Related product manuals