Key Features
High power density with up to 7200
VA /7200 Watts of power packed in just 3U rack space
Greater system uptime with support for Extended Runtime Modules (ERM)
Easy configuration through enhanced front panel display
Enterprise-wide intelligent manageability with bundled UPS Network Module and HP Power
Protector software
More efficient voltage regulation with revolutionary technology
Ultimate long-term battery reliability with HP Enhanced Battery Management
Enhanced system flexibility with two independently controlled load segments
Support for Remote Emergency Power Off (REPO) circuitry
Easy serviceability through modular design
Hot-Swappable Battery
Backed by a three year warranty with the first year including parts and labor. HP's Pre-Failure
warranty, and a $250,000 load protection guarantee
*
. (Certain restrictions and exclusions apply;
*Load protection guarantee available in North America only.
)
Optional Extended Runtime Modules (ERM) increase batter runtime during a power failure
4U Power Packed Design
Rated at unity power at 7200VA /7200W the HP UPS R7000 packs more power in space-conserving rack-
mount design, allowing you to support more critical equipment in your rack.
Increase System Uptime
with Extended Runtime
Modules
The Extended Runtime Modules are rack mounted battery modules that occupy 3U (5.25 inches) of rack
space. The HP UPS R7000 supports up to four Extended Runtime Modules (ERM), which extend your overall
battery runtime.
Lower Cost of Ownership
with Innovative
Technology
The HP UPS R7000 utilizes a the Digital Signal Processing industry-leading technology that continually
conditions and regulates power without using the battery, thereby increasing the life of the battery. The
output voltage is automatically regulated, based on the connected load and the input voltage.
Investment Protection
with HP Enhanced Battery
Management
HP UPS R7000 incorporates Enhanced Battery Management: an exclusive, patented technology that
doubles battery service life, optimizes battery recharge time, and provides advance notice of pending
battery failure. With Enhanced Battery Management, you can save 2-3 battery replacements over the life
of the UPS saving hundreds of dollars giving you a lower total cost of ownership while still receiving the
power protection for your critical equipment.
Enhanced Flexibility
Six C19 outlets, and two L6-30 outlet provide a wide range of connection options. Two included Extension
Bars provide an addition 14 C13 outlets if needed. Adding additional HP PDU Extension Bars, AF500A,
provides additional C13 outlets making the R7000 and extremely flexible UPS for all environments.
Remotely Monitor UPSs on
the Network
The installed UPS Network Module enables network administrators to remotely monitor UPSs and reboot
network devices. It provides SNMP functionality, including power event alerts, network power diagnostics,
and remote UPS reboot and testing. Used in conjunction with HP Systems Insight Manager or other SNMP
capable Network Management Software, power-related problems on the network are quickly discovered
and remedied.