Table 14: Error Messages
Error Message Description Suggested Repair
00 - 25 General software
flags
Power cycle the autoloader and run the Health test.
Check HP website for firmware updates.
26 Message Send ID
error
Check SCSI Bus cables and terminators.
Make sure the host bus adapter is installed,
detected, and configured properly.
Power cycle autoloader. Repeat checks after power
cycle.
27 Message bad
Check SCSI bus cables and terminators.
Make sure the host bus adapter is installed,
detected, and configured properly.
Power cycle autoloader. Repeat checks after power
cycle.
28 Message parameter
bad
Check host device driver.
Make sure the software application is supported,
has the autoloader correctly configured, and has
the latest patches installed.
Check SCSI bus cables and terminators.
Make sure the host bus adapter is installed,
detected, and configured properly.
Power cycle autoloader. Repeat checks after power
cycle.
29 Invalid element
Check host device driver.
Make sure the software application is supported,
has the autoloader correctly configured, and has
the latest patches installed.
Power cycle autoloader. Repeat checks after power
cycle.