Specifications
149SSL1016 Tape Autoloader Reference Guide
Environmental Specifications
Acoustic and Noise Limits
Table 19: Environmental Specifications
Temperature Range (Dry Bulb)
Operating +10ºC to +35ºC (+50ºF to +95ºF)
Non-operating - 35ºC to + 65ºC (-31ºF to +149ºF)
Temperature Variation
Operating 10ºC (50ºF) per hour
Non-Operating 20ºC (68ºF) per hour
Humidity
Operating 20% to 80% non-condensing
Non-Operating 10% to 90% non-condensing
Gradient 10% per hour
Wet Bulb
Operating 26ºC (78.8ºF) max
Non-Operating 29ºC (84.2ºF) max
Altitude
Operating -500 to 10,000 feet (-152 to 3,048 meters)
Non-Operating -500 to 30,000 feet (-152 to 9,144 meters)
Table 20: Acoustic and Noise Limits
Specification Operating
Storage or
Non-operating
Transportation
Acoustics Idle: not to exceed 55
dbA
Full operation: not to
exceed 60 dBA
N/A N/A