4130 600GB SAS
Storage
4330 450GB SAS
Storage
4330 900GB SAS
Storage
4330 1TB MDL
SAS Storage
4330FC 900GB
SAS Storage
4335 Hybrid
Storage
Dimensions
1U
1.7 x 17.1 x 27.5 inches (4.32 x 43.47 x 69.85 cm)
Weight
42.3 lb (19.2 kg)
Power/Cooling
Redundant Hot-Plug Common Slot Power Supplies
Auto-switching universal 115/220 Volts
@115V
607 BTU / h 705 BTU / h 721 BTU / h 676 BTU / h 808 BTU / h
912.28 BTU / h
177.12 Watts 213.29 Watts 217.75 Watts 204.82 Watts 243.55 Watts 267.53 Watts
@220V
600 BTU/hr 696 BTU/hr 710 BTU/hr 667 BTU/hr 797 BTU/hr
912.29 BTU / h
174.84 Watts 210.43 Watts
214.8 Watts
202.11 Watts 240.11 Watts 267.53 Watts
Environmental
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be limited
by the type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30°to 60°C (-22°to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity (non-
condensing)
Operating 10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet
bulb temperature, non-condensing.
Non-operating 5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum
wet bulb temperature, non-condensing.
Altitude
Operating 3048 m (10,000 ft). This value may be limited by the type and
number of options installed. Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating 9144 m (30,000 ft). Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Regulatory
FCC Rating: Class A
Normative Standards: CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1
QuickSpecs
HP StoreVirtual 4000 Storage
Technical Specifications
DA - 14437 Worldwide — Version 13 — December 9, 2013