2 Technical specifications
Physical specifications
D3600/D3610 LFF: 3.44 x 17.64 x 23.54 in (8.7 x 44.8 x 59.8 cm)Height/Width/Depth
D3700/D3710 SFF: 3.44 x 17.64 x 21.48 in (8.7 x 44.8 x 54.6 cm)
No disk drives: 38 lb (17.2 kg)Weight
D3700/D3710 SFF fully populated with SFF disk drives: 54.90 lb (24.9 kg)
D3600/D3610 fully populated with LFF disk drives: 60 lb (27.2 kg)
Power and environmental specifications
50° to 104° F (10° to 40° C)OperatingTemperature range (Temperature ratings
shown are for sea level. An altitude rating of
-22° to 149° F (-30° to 65° C)
NOTE: Rated 1°C per 1000 feet of elevation
to 10,000 ft.
Shipping
1°C per 300 m (1.8°F per 1,000 ft) to 3048 m
(10,000 ft) is applicable. The upper limit might
be limited by the type and number of options
installed.)
10% to 90% relative humidity (Rh)OperatingRelative humidity (Non-operating maximum
humidity of 95% is based on a temperature of
0% to 95% relative humidity (Rh)Non-operating
45°C (113°F). Altitude maximum for storage
corresponds to a pressure minimum of 70
KPa.)
82.4° F (28° C)Long-term storage
(operating)
Maximum wet bulb temperature
101.6° F (38.7° C)Short-term
storage
(non-operating)
3048 m (10,000 ft) This value might be limited
by the type and number of options installed.
OperatingAltitude (Maximum allowable altitude change
rate is 457 m/min (1500 ft/min))
9144 m (30,000 ft)Non-operating
100 to 240 VAC (Common-slot Power Supply)Input voltageInput power (Input Power and Heat Dissipation
specifications are maximum values and apply
50 to 60 Hz (Common-slot Power Supply)Input frequency
to worst-case conditions at full rated power
supply load. The power/heat dissipation for
120V power source: 6ARated input
current
your installation will vary depending on the
equipment configuration.)
240V power source: 3A
403WInput power (max)
Acoustic noise levels
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander
position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C
ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109). The listed sound levels apply to standard
shipping configurations. Additional options may result in increased sound levels.
LWAd= 7.0 BIdle Acoustic Noise (sound power)
LpAm - 53 dBAIdle Acoustic Noise (sound pressure)
18 Technical specifications

Table of Contents

Other manuals for HPE D3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE D3000 and is the answer not in the manual?

HPE D3000 Specifications

General IconGeneral
BrandHPE
ModelD3000
CategoryEnclosure
LanguageEnglish

Related product manuals