Small Form Factor D37x0 disk enclosures — maximum capacity
configuration
This example illustrates cabling for a single-domain configuration. In this configuration, note the
following:
• P1 on the disk enclosure I/O module is treated as the SAS “in” port.
• P2 on the disk enclosure I/O module is treated as the SAS “out” port.
• In single-domain configurations, one cable path is created between the host, the primary
disk enclosure, and additional cascaded disk enclosures. (Shown)
• In dual-domain configurations, two cable paths are created between the host, the primary
disk enclosure, and additional cascaded disk enclosures.
1. Host (server or controller enclosure)
2. Primary disk enclosure
3. Additional cascaded disk enclosure
Small Form Factor D37x0 disk enclosures — maximum capacity configuration 45