Technical white paper Page 9
Supported upgrade paths for the HPE MSA 1040/2040
Table 4 shows a list of the supported upgrade paths covered in this document.
Table 4. Supported upgrade paths
Description
From
To
Dual controller
P2000 G3 FC MSA5
6
P2000 G3 FC/iSCSI MSA
6
P2000 G3 SAS MSA
6
P2000 G3 10GbE iSCSI MSA
6
P2000 G3 iSCSI MSA
6
HPE MSA 1040 2-port 10GbE iSCSI6F
7
HPE MSA 1040 2-port 1GbE iSCSI
7
HPE MSA 1040 2-port 8Gb FC
7
HPE MSA 1040 2-port SAS
7
Single or dual controller
P2000 G3 FC MSA
6
P2000 G3 FC/iSCSI MSA
6
P2000 G3 SAS MSA
6
P2000 G3 10GbE iSCSI MSA
6
P2000 G3 iSCSI MSA
6
HPE MSA 2040/2042 SAN
8
HPE MSA 2040/2042 SAS
Single or dual controller
HPE MSA 2040/2042 SAN
6
HPE MSA 2040/2042 SAS
6
HPE MSA 2040/2042 SAS
HPE MSA 2040/2042 SAN
Dual controller
HPE MSA 1040 2-port 10GbE iSCSI
6
HPE MSA 1040 2-port 1GbE iSCSI
6
HPE MSA 1040 2-port 8Gb FC
6
HPE MSA 1040 2-port SAS
6
HPE MSA 2040/2042 SAN
HPE MSA 2040/2042 SAS
Dual controller
HPE MSA 1040 2-port 10GbE iSCSI
6
HPE MSA 1040 2-port 1GbE iSCSI
6
HPE MSA 1040 2-port 8Gb FC
6
HPE MSA 1040 2-port SAS
6
HPE MSA 1040 2-port 10GbE iSCSI
HPE MSA 1040 2-port 1GbE iSCSI
HPE MSA 1040 2-port 8Gb FC
HPE MSA 1040 2-port SAS
Note
This white paper examines single-to-single controller upgrades and dual-to-dual controller upgrades. This white paper does not examine
single-to-dual or dual-to-single controller upgrades.
The MSA 2040/2042 SAS controller supports up to four 6Gb SAS or 12Gb SAS connections per controller using mini-SAS HD connectors
and upgrading from a P2000 G3 SAS storage system will require new host connect cables.
The following table lists the supported SFP locations on the MSA 2040/2042 controller ports when using Fibre Channel, iSCSI, and the combination
of Fibre Channel and iSCSI. For dual controller systems, symmetrical SFP placement is required.
Table 5. Supported MSA 2040/2042 SAN controller host ports and SFP locations
Host Port 1 SFP8F
8
Host Port 2 SFP
8
Host Port 3 SFP
9
Host Port 4 SFP
9
8/16 Gb Fibre Channel
8/16 Gb Fibre Channel
None
None
8/16 Gb Fibre Channel
8/16 Gb Fibre Channel
1/10 Gb iSCSI
1/10 Gb iSCSI
1/10 Gb Fibre Channel
1/10 Gb Fibre Channel
None
None
1/10 Gb iSCSI
1/10 Gb iSCSI
6
LUN mappings using a protocol different from the original controller (such as changing from iSCSI to Fibre Channel) will be deleted during the upgrade and need to be
remapped.
7
The MSA 1040 storage system ships standard with dual controllers and a storage enclosure. Drives from a P2000 G3 storage system must be moved to the MSA 1040
storage system enclosure during the upgrade process and placed in the MSA 1040 system in the same order, as they were in the P2000 G3 storage enclosure if possible, for
consistency. The same drive order is recommended to maintain consistency with the original layout and any documentation that might exist. However, it is not required
because the metadata with be identified by the MSA 1040 controllers. You should move drives only while the system is offline.
8
SFP in host Port 1 must match SFP in host Port 2.
9
SFP in host Port 3 must match SFP in host Port 4.

Related product manuals