3. Power down the server (Power down the server on page 23).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Do one of the following:
• Server in rack mode: Remove the server from the rack on page 23.
• Server in tower mode: Position the tower server for hardware configuration on page 25.
7. Remove the access panel on page 25.
8. Remove the PCI air baffle on page 29.
9. Remove the system air baffle on page 30.
10. Remove any components or cables that may prevent access to the TPM connector.
11. Proceed to Installing the TPM board and cover on page 95.
Installing the TPM board and cover
Procedure
1. Observe the following alerts:
CAUTION: If the TPM is removed from the original server and powered up on a different server, data
stored in the TPM including keys will be erased.
CAUTION: The TPM is keyed to install only in the orientation shown. Any attempt to install the TPM
in a different orientation might result in damage to the TPM or system board.
2. Align the TPM board with the key on the connector, and then install the TPM board. To seat the board,
press the TPM board firmly into the connector. To locate the TPM connector on the system board, see the
server label on the access panel.
Hardware options installation 95