Shenzhen Hpmont Technology Co., Ltd Chapter 6 Function Introduction
HD30 Series Inverters User Manual 79
No. Name Description Range
factory setting
F13.07 Parameter auto-tuning of motor 2 0
2
0
F13.08 Stator resistance of motor 2 above 5.5KW 0.000
9.999Ω
dependent on
inverter model
5.5KW or below 0.00
99.99Ω
dependent on
inverter model
F13.09 Rotor resistance of motor 2 above 5.5KW 0.000
9.999Ω
dependent on
inverter model
5.5KW or below 0.00
99.99Ω
dependent on
inverter model
F13.10 Leakage inductance of motor 2 above 5.5KW 0.0
999.9mH
dependent on
inverter model
5.5KW or below 0
9999mH
dependent on
inverter model
F13.11 Mutual inductance of motor 2 above 5.5KW 0.0
500.0mH
dependent on
inverter model
5.5KW or below 0
5000mH
dependent on
inverter model
F13.12 Idling exciting current of motor 2 above 5.5KW 0.0
999.9A
dependent on
inverter model
5.5KW or below 0.00
99.99A
dependent on
inverter model
F13.13
Reserved
F13.14 Reserved
F13.15
Reserved
F13.16 V/f curve selection of motor 2 0
4
0
0: Line.
1: Square curve.
2: 1.2 exponential curve.
3: 1.7 exponential curve.
4: User-defined curve.
F13.17 V/f frequency value F3 of motor 2 F13.19
F13.04
0.00Hz
F13.18
V/f voltage value V3 of motor 2
F13.20F13.020V
F13.19 V/f frequency value F2 of motor 2 F13.21
F13.17
0.00Hz
F13.20
V/f voltage value V2 of motor 2
F13.22F13.180V
F13.21 V/f frequency value F1 of motor 2 0.00
F13.19
0.00Hz
F13.22
V/f voltage value V1 of motor 2
0F13.200V
F13.23 Torque boost of motor 2 0,0.1
30.0%
0.1
F13.24
Cut-off point used for manual torque boost of motor 2
0.050.0% (F13.04)10.0%
F13.25 Slip compensation gain of motor 2 0.0
300.0%
100.0
F13.26
Slip compensation filter time of motor 2
0.0110.00s0.10
F13.27 Slip compensation limitation of motor 2 0.0
250.0%
200.0
F13.28
Compensation constant of motor 2
0.125.0s2.0
F13.29 Reserved
F13.30
AVR (automatic voltage regulation) function of motor 2
022
F13.31 Oscillation-suppression mode of motor 2 0,1
1
F13.32
Oscillation-suppression coefficient of motor 2
020050
6

Table of Contents

Other manuals for hpmont HD30-4T5P5G/7P5P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the hpmont HD30-4T5P5G/7P5P and is the answer not in the manual?

hpmont HD30-4T5P5G/7P5P Specifications

General IconGeneral
Brandhpmont
ModelHD30-4T5P5G/7P5P
CategoryInverter
LanguageEnglish

Related product manuals