EasyManuals Logo

HT HT65 User Manual

Default Icon
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
HT65
EN - 21
Capacitance (Autorange)
Range Resolution Accuracy Overload protection
40.00nF 0.01nF
r(5.0%rdg + 7dgt)
250VDC/ACrms
400.0nF 0.1nF
r(3.0%rdg + 5dgt)
4.000PF 0.001PF
40.00PF 0.01PF
400.0PF 0.1PF r(5.0%rdg + 5dgt)
4.000mF 0.001mF
r(10%rdg)
40.00mF 0.01mF
Temperature with K-type probe (Autorange)
Range Resolution Accuracy (*)
Overload protection
-20°C ÷ 760°C 1°C
r(3.0%rdg + 5°C)
250VDC/ACrms
-4°F ÷ 1400°F 1°F
r(3.0%rdg + 9°F)
(*) Instrument accuracy with no probe
7.1.1. Reference standards
Safety: IEC/EN61010-1
EMC: IEC/EN 61326-1
Insulation: double insulation
Pollution level: 2
Overvoltage category: CAT IV 600V, CAT III 1000V to ground
7.1.2. General characteristics
Mechanical characteristics
Size (L x W x H): 175 x 85 x 55mm (7 x 3 x 2in)
Weight (batteries included): 360g (13 ounces)
Mechanical protection: IP40
Power supply
Battery type: 1x9V battery type IEC 6F22
Low battery indication: symbol
“” on the display
Battery life: ca.45h (backlight ON), ca 60h (backlight OFF)
Auto Power Off: after 15 minutes
idling (can be disabled)
Display
Conversion: TRMS
Characteristics: 4 LCD, 4000 dots, decimal sign, point and
backlight
Sampling frequency: 3 times/s