Item
Test Condition
Standard
Sample
size
Results
High-temperature
storage
Temperature: 85ºC
Operation mode: no
power, no package
Test duration: 24 h
JESD22-
A103-C
3
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Low-temperature
operating
Temperature: 20ºC
Operation mode: working
with service connected
Test duration: 24 h
IEC6006
8-2-1
3
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
High-temperature
operating
Temperature: 70ºC
Operation mode: working
with service connected
Test duration: 24 h
JESD22-
A108-C
3
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Damp heat
cycling
High temperature: 55ºC
Low temperature: 25ºC
Humidity: 95%±3%
Operation mode: working
with service connected
Test duration: 6 cycles;
12 h+12 h/cycle
JESD22-
A101-B
3
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Thermal shock
Low temperature: 40º
High temperature: 85ºC
Temperature change
interval: < 20s
Operation mode: no
power
Test duration: 100 cycles;
15 min+15 min/cycle
JESD22-
A106-B
3
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Salty fog test
Temperature: 35°C
Density of the NaCl
solution: 5%±1%
Operation mode: no
power, no package
Test duration:
Spraying interval: 8 h
Exposing period after
removing the salty fog
environment: 16 h
JESD22-
A107-B
3
pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok