Huawei OceanStor S2600 - Failing to Log In to ISM

Huawei OceanStor S2600
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Procedure
l Cause 1: The management network port of the array is not properly connected.
1. Remove and insert the data transmission cable or replace the data transmission cable.
2. Rediscover the system. The arrays to be managed are discovered on the ISM.
l Cause 2: The version of the ISM is incorrect.
1. Log in to the ISM download interface to download and install the latest version of the
ISM. For details, see the OceanStor S2600 Storage System User Guide.
2. Rediscover the system. The arrays to be managed are discovered on the ISM.
l Cause 3: The IP address, user name, or password of the array are incorrect.
1. Enter the correct IP address, user name, and password of the array and log in to the
ISM.
2. Rediscover the system. The arrays to be managed are discovered on the ISM.
l Cause 4: The IP address of the NIC of the maintenance terminal incorrect.
1. Check the network segment of the IP address of the maintenance terminal.
2. Check the IP address list of the NIC of the maintenance terminal that communicates
with the management network port of the controller, and set the first IP address in the
list to be in the same network segment with the current maintenance terminal.
3. Rediscover the arrays. The arrays to be managed are discovered on the ISM.
----End
5.12 No Output from the CLI Serial Port
This section describes how to handle the fault that no information is output from the CLI serial
port.
Symptom
After the serial port on the maintenance terminal is connected to the serial port in the storage
system, the maintenance terminal cannot receive information output from the CLI serial port in
the storage system.
Possible Causes
One of the following causes may arouse no output from the CLI serial port:
l
The serial port cable is improperly connected.
l The rate of the serial port on the maintenance terminal is inconsistent with that of the CLI
serial port in the storage system.
Fault Diagnosis
You can determine the cause for the fault through the following procedure:
l Cause 1: The serial port cable is improperly connected.
1. Remove and insert the CLI serial port cable again or replace the CLI serial port cable.
2. If the maintenance terminal receives information from the CLI serial port, you can
determine that the fault is caused by improper connection of the serial port.
OceanStor S2600 Storage System
Troubleshooting 5 Troubleshooting of Common Faults
Issue 03 (2010-01-28) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5-17