3.2 Process Description
This section describes the main steps in the troubleshooting process.
Observing and Recording the Indicator Status
You can locate the faulty module by observing the indicator status.
Table 3-1 lists the indicators of each component.
Table 3-1 Indicators of each component
Module Type of indicators Color Status Description
System
enclosure
Startup/Alarm
indicator of the
controller enclosure
Red On The controller enclosure is not
in service or an alarm is
generated on the controller
enclosure.
NOTE
When the indicator is red for a
along time, it indicates that a
critical fault occurs in the system.
Orange
Blinking The controller enclosure is
starting.
- Off The controller enclosure runs
normally.
Power indicator of
the controller
enclosure
Green On The controller enclosure is
powered on.
- Off The controller enclosure is not
powered on.
Disk
module
Disk running
indicator
Green Blinking Data is being transmitted from
or to the disk.
Green On The disk is powered on
normally.
- Off The disk is powered on
abnormally.
Alarm/Location
indicator of the SAS
disk
Red On An alarm is generated on the
disk.
Red Blinking The disk is located.
- Off No alarm is generated on the
disk.
Fan module Fan running/alarm
indicator
Green On The fan is normal.