Module Type of indicators Color Status Description
Red On An alarm is generated on the
fan.
- Off The fan module is powered on
abnormally.
Power
module
Power running/
alarm indicator
Green On The power supply is normal.
Orange Blinking An alarm is generated on the
power supply.
- Off The controller enclosure is not
powered on or the power
module is powered on
abnormally.
Controller Active indicator of
the management
network port
Orange Blinking Data is being transmitted.
- Off No data is transmitted.
Link indicator of the
management
network port
Green On The link of the management
network port is normal.
- Off The link of the management
network port is abnormal.
Controller power
indicator
Green On The controller is powered on
normally.
- Off The controller is powered on
abnormally.
Controller alarm
indicator
Red On An alarm is generated on the
system.
Red On, and
off after
five
seconds;
on and
then off
after the
controller
starts
normally
The controller is starting.
- Off The system is normal.
Link indicator of the
mini SAS expander
port
Green On The disk channel is normal.
- Off The disk channel is abnormal.
Link indicator of the
FC host port
Green On The connection between the
storage system and the AS is
normal.
3 Troubleshooting Process
OceanStor S2600 Storage System
Troubleshooting
3-4 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 03 (2010-01-28)